Home | Applied Membranes Home | Purchase Online | Common Q & A | Technical Articles | Design Information  


Nominal Rejection Characteristics of:

TFC Elements

or

CTA Elements

 

Or CLICK HERE to view a comparison of membrane processes.

Nominal Rejection Characteristics of Thin Film Composite Reverse Osmosis Membranes

Ion

% Rejection*

Calcium

93-99

Sodium 92-98
Magnesium 93-98
Potassium 92-96
Manganese 96-98
Iron 96-98
Aluminum 96-98
Copper 96-99
Nickel 96-99
Cadmium 93-97
Silver 93-96
Zinc 96-98
Mercury 94-97
Hardness Ca&Mg 93-97
Radioactivity 93-97
Chloride 92-98
Ammonium 80-90
Ion % Rejection*
Bromide 90-95
Phosphate 95-98
Cyanide 90-97
Sulfate 96-99
Thiosulfate 96-98
Silicate 92-95
Silica 90-98
Nitrate 90-95
Boron 50-70
Borate 30-50
Fluoride 92-95
Polyphosphate 96-98
Orthophosphate 96-98
Chromate 85-95
Bacteria 99+
Lead 95-98
Arsenic 50-90

Nominal Rejection Characteristics of Cellulose Triacetate Reverse Osmosis Membranes

Ion % Rejection*
Sodium 90-95
Calcium 92-95
Magnesium 94-97
Potassium 85-95
Iron 92-96
Manganese 92-96
Aluminum 95-98
Ammonium 85-90
Copper 96-98
Nickel 96-98
Zinc 96-98
Strontium 95-97
Cadmium 95-97
Silver 90-95
Mercury 94-96
Barium 94-96
Chromium 94-96
Ion % Rejection*
Lead 94-96
Chloride 90-95
Bicarbonate 85-95
Nitrate 50-70
Fluoride 85-90
Silicate 80-90
Phosphate 95-97
Chromate 80-90
Cyanide 80-90
Sulfite 94-96
Thiosulfate 94-97
Ferrocyanide 96-98
Bromide 85-90
Borate 25-50
Sulfate 96-98
Arsenic 90-95
Selenium 90-95

 
Back Home Up Next

 Determining SDI What's Nanofiltration Membrane Rejection Levels Temperature Correction Pressure Correction Membrane Spectrum

All Content on this site is  intended for informational purposes for experienced water treatment professionals only.  Applied Membranes, Inc. does not assume any liability for any damages caused by the misapplication or misinterpretation of any of the information contained on this website.
© Applied Membranes, Inc. 2007